Repository logo
Communities & Collections
All of TUK IR
  • English
  • العربية
  • বাংলা
  • Català
  • Čeština
  • Deutsch
  • Ελληνικά
  • Español
  • Suomi
  • Français
  • Gàidhlig
  • हिंदी
  • Magyar
  • Italiano
  • Қазақ
  • Latviešu
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Српски
  • Svenska
  • Türkçe
  • Yкраї́нська
  • Tiếng Việt
Log In
New user? Click here to register. Have you forgotten your password?
Communities & Collections
All of TUK IR
  1. Home
  2. Browse by Author

Browsing by Author "Okwdha, GDO"

Filter results by typing the first few letters
Now showing 1 - 1 of 1
  • Results Per Page
  • Sort Options
  • No Thumbnail Available
    Item
    Biocontainment of polychlorinated biphenyls (PCBs) on flat concrete surfaces by microbial carbonate precipitation
    (2011) Li, Jin; Okwdha, GDO
    In this study, a biosealant obtained from microbial carbonate precipitation (MCP) was evaluated as an alternative to an epoxy-coating system. A bacterium Sporosarcina pasteurii strain ATCC 11859, which metabolizes urea and precipitates calcite in a calcium-rich environment, was used in this study to generate the biosealant on a PCB-contaminated concrete surface. Concrete cylinders measuring 3 in (76.2 mm) by 6 in (152.4 mm) were made in accordance with ASTM C33 and C192 and used for this purpose. The PCB, urea, Ca2+, and bacterial cell concentrations were set at 10 ppm, 666 mM, 250 mM, and about 2.1 × 108 cells mL−1, respectively. The results indicate that the biosealed surfaces reduced water permeability by 1–5 orders of magnitude, and had a high resistance to carbonation. Since the MCP biosealant is thermally stable under temperatures of up to 840 °C, the high temperatures that normally exist in the surrounding equipment, which may contain PCB-based fluids, have no effect on the biosealed surfaces. Consequently, there is greater potential to obtain a stronger, coherent, and durable surface by MCP. No measurable amount of PCBs was detected in the permeating water, indicating that the leaching water, if any, will have a minimum impact on the surrounding environment.

Quick Links

  • TUK Website
  • Library
  • Privacy Policy
  • Access to information Requests

Useful Links

  • Accessibility Statement
  • Takedown Policy

   Haile Selassie Avenue,
P.O. Box 52428 - 00200,
Nairobi
        Phone: +254(020) 2219929,
    3343672
       Email: library@tukenya.ac.ke

The Technical University of Kenya copyright © 2002-2026
Cookie settings | Privacy policy | End User Agreement | Send Feedback